1 x TDK-Lambda Isolated DC-DC Converter CN30A110-5, Vin 60-160V dc, Vout 5V dc, - TDK-Lambda
TDK-Lambda
TDK-Lambda Isolated DC-DC Converter, Vin 60 → 160 V dc, Vout 5V dc, I/O isolation 3kV ac
- BMUK Part # :-764-9264
- BrandTDK-Lambda
- Mfr. Part No.CN30A110-5
-

- You will get 1 DC-DC Converter

TDK Lambda CN-A Series, 30W to 200W 110VDC Input, Quarter Brick & Half Brick Railway Isolated DC-DC Converter
CN-A series, 30 to 200W 24Vdc input, railway isolated DC-DC converters with a compact quarter-brick and half brick design (CN30A - 100A: 36.8 x 12.7 x 57.9mm, CN200A: 61 x 12.7 x 57.9mm) that uses less PCB space, a wide input voltage range of 60 to 160 Vdc and full regulation. These 30 to 200W railway-isolated DC-DC converters comply with the applicable railway standards and are designed for harsh environments, meeting the shock and vibration requirements of IEC61373 Category 1 Class B. A true useable power from -40 to +100°C without derating can be provided by these railway-isolated DC-DC converters which are base-plate cooled, they can also offer up to 88% efficiency and up to 4.2A useable output current. Typical uses for these railway-isolated DC-DC power modules include battery-powered railway systems such as rolling stock and fixed installations, power plants, and customer power supplies.
Wide 60 - 160Vdc Input to EN50155/IEC60571
Compliant with applicable railway standards
Shock and vibration compliant to IEC61373 Category 1 Class B
Full power from -40˚C to +100˚C without derating (covers TX class for Railway)
Base plate cooled
High efficiency of up to 88%
Up to 4.2A useable output current
3kVac input/output isolation
Remote sensing and remote on/off functions
Overvoltage and overcurrent protection
Undervoltage lockout function (UVLO)
Protects the battery against deep discharges
Compact size: CN30A - 100A: 36.8 x 12.7 x 57.9mm, CN200A: 61 x 12.7 x 57.9mm
Standards
UL60950-1, CSA60950-1, EN60950-1, CE LVD
TDK Lambda 100 to 200W Railway Isolated DC-DC Converters
| Output Voltage | 5V dc | |
| Input Voltage Range | 60 → 160 V dc | |
| Input Voltage Nominal | 110 V dc | |
| Isolation Voltage | 3kV ac | |
| Output Current | 6A | |
| Mounting Type | Through Hole | |
| Number of Outputs | 1 | |
| Package | 1/4 Brick | |
| Efficiency | 83% | |
| Minimum Temperature | -40°C | |
| Maximum Temperature | +100°C | |
| Load Regulation | 40mV | |
| Line Regulation | 20mV | |
| Length | 57.9mm | |
| Ripple And Noise | 100mV Pk-Pk | |
| Depth | 12.7mm | |
| Weight | 70g |